Important Safety

Read these instructions before using the Vortex DBF-DEDPV Dryer Booster Fan Instruction Manual.

  • Your dryer installation incorporates a dryer exhaust power ventilator (DEDPV) incorporating a lint trap.
  • Your dryer depends on the DEDPV for its safe and efficient operation.
  • Do not install in an exhaust ductwork of a clothes dryer whose instructions prohibit the installation of a clothes dryer booster fan (DEDPV).
  • Do not install in exhaust ductwork where the equivalent duct length is less than 25 ft (7.62 linear meters).

Installation

DBF-DEDPV
The DBF-DEDPV incorporates a booster fan, a lint trap, and an integrated indicator panel.Vortex-DBF-DEDPV-Dryer-Booster-Fan-fig 1

Mounting  DBF-DEDPV

The visual indicator shall be visible to the dryer operator and the lint trap shall be easily accessible to the operator for cleaning. Refer to maintenance instructions for inspection recommendations.

Metal housing
Vortex-DBF-DEDPV-Dryer-Booster-Fan-fig 3Spacing: Ensure to leave the appropriate spacing corresponding to the drywall thickness 1/2’’ or 5/8’’ between the face of the stud and the front of the box edge corresponding to distance ‘’D’’ as shown above.

Vortex-DBF-DEDPV-Dryer-Booster-Fan-fig 4Mount housing directly to the stud using provided wood or metal screws. Ensure to use the oblong slot. Orientation: Refer to the orientation sticker to install the housing in the proper orientation.

Install Ductwork
Vortex-DBF-DEDPV-Dryer-Booster-Fan-fig 5Install a 4’’ rigid galvanized duct on the inlet and outlet. Do not use a screw to attach the duct to the DBF-DEDPV duct adapter, use aluminum tape to seal the connections.

Electrical connection

Vortex-DBF-DEDPV-Dryer-Booster-Fan-fig 6

  • A – Install the electrical connector to the housing.
  • B – Bring a 2/14 AWG wire from a dedicated circuit.
  • C – Connect the junction box connector wires to the 115 V supplied wires and the housing ground wire.
  • D – Close back the junction box with the supplied screw.

Frame isolation
Vortex-DBF-DEDPV-Dryer-Booster-Fan-fig 7Once the drywall is installed, insert the frame inside the housing ensuring that it is in the proper orientation. The two-front holes should be face down as shown above.

Frame fixation
Vortex-DBF-DEDPV-Dryer-Booster-Fan-fig 8Before fixing the frame to the housing with the provided screws, ensure that the screw holes in the frame are aligned with the screw holes in the housing. If the holes are not aligned, loosen the screw that holds the housing to the stud and adjust the depth of the housing until the holes are aligned.

Fan connection
Vortex-DBF-DEDPV-Dryer-Booster-Fan-fig 9Before inserting the fan, connect the DBF-DEDPV male connector to the junction box female connector.

  • A – Insert the fan unit in the housing.
Fan unit locking procedure
Vortex-DBF-DEDPV-Dryer-Booster-Fan-fig 10
  • B – Push the top fan unit towards the housing.
  • C – Tilt the fan unit as shown on the above.
  • D – Slide the fan unit towards the top.

Fix the fan unit
Vortex-DBF-DEDPV-Dryer-Booster-Fan-fig 11Once the holes of the fan unit are aligned with the holes of the housing, put and hand tighten the metal screws. Ensure no oversight to avoid stripping the holes in the housing.

Lint tray insertion
Vortex-DBF-DEDPV-Dryer-Booster-Fan-fig 12Insert the lint tray in the fan unit.

Warning notification
Vortex-DBF-DEDPV-Dryer-Booster-Fan-fig 13Apply the provided warning and operational stickers on the unit.

Operation

DBF-DEDPV Calibration procedure
  • Confirm that the power of the clothes dryer is turned off.
  • Confirm all lint traps are empty of lint and reinstalled in their proper position.
  • Confirm the clothes dryer is empty of clothing.
  • Confirm the door on the dryer is closed.
  • From the electrical panel, turn on the power to the DBF-DEDPV.

Notification Panel Status Mode

CALIBRATION MODE (Flashing blue light)

PROPER VENTING MODE (Steady green indicator light) When the DBF-DEDPV is on, the green indicator light will be continuously on.

PRESSURE FAULT MODE (Flashing orange indicator light)

If, at any time during the calibration or operating cycle of the DBF-DEDPV, a flashing orange indicator light appears, the DBF-DEDPV pressure sensor is detecting a rise of static pressure in the duct due to a blockage to the system. The DBF-DEDPV will continue to work but you must stop the clothes dryer immediately and have the vent system inspected by a qualified service provider.

CIRCUIT FAILURE MODE (Flashing pink indicator light)

If, at any time during the calibration of the operating cycle a flashing pink indicator light appears the DBF-DEDPV is not functioning properly due to a circuit or motor failure, stop the dryer immediately, turn off the power of the DBF DEDPV, and contact the manufacturer.

TEMPERATURE FAULT MODE (Flashing red indicator light)

This is a safety design feature to prevent the DBF-DEDPV from operating during abnormal or dangerous drying conditions. If this occurs, contact the manufacturer.

Read this instruction before using the Vortex DBF-DEDPV Dryer Booster Fan Instruction Manual.

Maintenance

Depending on use, but no longer than once a year, Atmosphere recommends cleaning the clothes dryer exhaust vent. On an annual basis make sure that the exhaust hood flapper or backdraft damper is clean of lint and moves freely. The DBF-DEDPV motor is maintenance-free. If the DBF-DEDPV is not functioning as it should, perform the calibration procedure. (See calibration instructions for complete details) The fan impeller may accumulate lint.

To inspect and clean the impeller :
  • Turn off power at the source
  • Remove the fan unit from the housing of the DBF-DEDPV and clean any lint buildup on the impeller and near the inlet and outlet.
  • Reinstall the fan unit. Turn the power back on and recalibrate the unit. (See calibration instructions for complete details)

Troubleshooting

  • Maximum exhaust temperatures should not exceed 167°F. If the safety thermal fuse in the DBF-DEDPV trips, the clothes dryer is operating outside standard code limits. Contact the clothes dryer manufacturer or authorized service provider and replace the DBF-DEDPV.
  • If the clothes dryer is operating normally, and there is no green indicator light on the notification panel, stop the clothes dryer immediately, and have the vent system inspected and cleaned by an authorized service provider.

Stop the clothes dryer immediately. Have the vent system inspected and cleaned by an authorized service provider? This is an indication of excessive back pressure in the vent system

Wiring Diagram

Vortex-DBF-DEDPV-Dryer-Booster-Fan-fig 14

Read these instructions before using the Vortex DBF-DEDPV Dryer Booster Fan Instruction Manual.

Warranty

Ten (10) Year Warranty  This warranty supersedes all prior warranties

Atmosphere will repair or replace any part that has a factory defect in workmanship or material. The product will need to be returned to the Atmosphere factory, together with a copy of the purchase invoice, and identified with the RMA number.

  • Have a Return Materials Authorization (RMA) number. This may be obtained by contacting Atmosphere at info@atmosphere.com. Please have a copy of the purchase invoice available.
  • The RMA number must be written on the outside of the box or it will be refused.

Contact Information

Website: www.atmosphere.com
Email: info@atmosphere.com.

Amazon Save Offer

For More Manuals

Download Pdf

This Post Has One Comment

  1. vpn coupon code 2024

    Howdy are using WordPress for your site platform?

    I’m new to the blog world but I’m trying to get started and create my own. Do you require any html
    coding knowledge to make your own blog? Any help would be really
    appreciated!

    my web page; vpn coupon code 2024

Leave a Reply