INFRARED THERMOMETER
Features:

  1. Precise non-contact measurements
  2. bullaun laser pointer
  3. Automatic selection 0.1’C/’C
  4. °C/*F switchable button
  5. Automatic Data Hold & AutoRowerr off
  6. The thermometer at ” inches away measure ” inch target
  7. back! Loo display
  • Useful Applications
    This thermometer is verdict for checking the temperature of chizz stones to know when you are ready to cook. You can also use it to scan your grill surface and lenity no ano cow spoils tor better online
  • Field of ViewThe thermometer’s field of view is 12:1, meaning that if the thermometer is 1Ziches from the target the diameter of the object under test must be diagram. Rater to the chart oriented on the thermometer for more informationCuisinart CSG-625 Infrared- Surface- Thermometer- User- Guide-fig-1

1 .SAFETYBee careful when the laser beam is fumed on Do not let the beam enter your eye, another person’s eye or the eyes of an animal do carrot not to let the beam on a collective surface in case reflects me beam eyes.

Do not allow the laser light beam to  impinge on any gas or area which

SPECIFICATIONSCuisinart CSG-625 Infrared- Surface- Thermometer- User- Guide-fig-2

General specifications

Note:
Accuracy is given at 18°C to 28°C (64°F to 82°F), less than 80%RH. Field of View: Make sure that the target is larger than the unit’s spot size. The smaller the target, the closer you should be to I, When accuracy is critical, make sure the target is at least is at least twice as large as the spot size. Emissivity: 0.95 fixed value

. FRONT PANEL DESCRIPTIONCuisinart CSG-625 Infrared- Surface- Thermometer- User- Guide-fig-3

  1.  IR sensor
  2.  Laser pointer beam
  3. B LCD Display
  4.  Laser select key
  5.  Backlight
  6. Max/Min Temperature °C/°F
  7. Measurement Trigger
  8.  Battery Cover
  9. Handle Grip

4. INDICATORCuisinart CSG-625 Infrared- Surface- Thermometer- User- Guide-fig-4

  1.  Digital readout
  2.  Temperature C (Celsius)
  3.  Temperature F (Fahrenheit)
  4.  Measuring indication
  5.  Data Hold
  6.  LOW battery indicator
  7.  Laser Point
  8.  Fixed emissivity (0 95)

5. MEASUREMENT OPERATION

  1.  Hold the meter by its Handle Grip and point it toward the surface to be measured.
  2. Pull and hold the Trigger to turn the meter on and begin testing. The display will light if the battery is good. Replace the battery if the display does not light.
  3. While measuring, the SCAN display icon will appear in the upper left-hand corner of the LCD.
  4.  Push the Laser button to turn on the laser pointer. When the laser turns on, the laser icon < will appear on the LCD over the temperature. Aim at the red beam approximately a half inch above the point of the test (pressing the Laser button again turns the laser off).
  5.  Select the temperature units (°C or °F) using the °C and °F buttons.
  6.  Push the Backlight key to turn on the LCD backlight function.
  7.  Pressthe  “Mode” button to changethe  Max/Min Value.
  8. The meter will automatically power down after approximately 7 seconds after the trigger is released.

Note: Measurement considerations Holding the thermometer by its handle, point the I Sensor toward the object whose temperature is to be measured. The thermometer automatically compensates
for temperature deviations from ambient temperature. Keep in mind that it will take up to 30 minutes to adjust if the wide ambient temperature is to be measured following high-temperature measurements, several minutes are required after the low(and before the high) temperature measurements are made. This is a result of the cooling process which must take place for the IR sensor.

6. Battery ReplacementCuisinart CSG-625 Infrared- Surface- Thermometer- User- Guide-fig-5

  1.  When the battery is low, the LCD will display” at”
  2.  Open the battery cover and replace it with a new 9-volt battery.

7. NOTES:

  •  How it works Infrared thermometers measure the surface temperature of an object. The unit’s optics sense emitted, reflected, and transmitted energy, which is collected and focused onto a detector. The unit’s
  • electronics translate the information into a temperature reading which is displayed on the unit. In units with a laser, the laser is used for aiming purposes only.
    Field of View
    Make sure that the target is larger than the unit’s spot size. The smaller the target, the closer you should be to it. When accuracy is critical, make sure the target is at least twice as large as the spot size.
    Distance & Spot Size As the distance (D) from the object increases, the spot size(S) of the area measured by the unit becomes larger. See: Fig 1.
  •  Locating a Hott Spot
    To find a hot spot aim the thermometer outside the area of interest, then scan across with an up-and-down motion until you locate the hot spot.
  • Reminders
    Not recommended for use in measuring shiny or polished metal surfaces (stainless steel, aluminum, etc. See Emissivity ( The unit cannot measure through transparent surfaces. It will measure the surface temperature of the glass instead. 3 Steam, dust, smoke, etc., can prevent accurate measurement by obstructing the unit’s optics.
  •  Emissivity
    Most (90% of typical applications) organic materials and painted or oxidized surfaces have an emissivity of 0.95 (pre-set in the unit). inaccurate readings will result from measuring shiny or polished metal
    surfaces. To compensate, cover the surface to be measured with masking tape or flat black paint. Allow time for the tape to reach the same temperature as the material underneath it. Measure the temperature