INTRODUCTION

  • Thank you for having chosen a blood pressure monitor ORBEGOZO.
  • The unit uses the oscillometric method of blood pressure measurement. It means the unit detects the movement of your blood through your brachial artery and converts your blood pressure into a digital reading. The unit is simple to use because a stethoscope is not needed while using an oscillometric monitor.
  • The unit stores automatically 60 sets of measurement values for each user (2×60). You can read the stored data conveniently by pressing the memory button.
  • The unit comes with the following components: main unit, arm cuff, and Orbegozo TES 3650 Blood Pressure Monitor User Manual.

SYMBOLS IN THIS MANUAL AND PRODUCT

  • Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 1Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
  • Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 2Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
  • Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 3Type B applied part
  • Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 4 Transport packages should be kept away from the rain.
  • Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 5Authorised representative in the European community
  • Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 6Refer to the instruction manual/booklet
  • Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 7Manufacturer
  • Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 8Serial number
  • Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 9The marking of electrical and electronic devices according to Directive 2002/96/EC. The device, accessories, and packaging have to be disposed of waste correctly at the end of the usage. Please follow Local Ordinances or Regulations for disposal.

USING AND SAFETY INSTRUCTIONS

To ensure the correct use of the product basic safety measures should always be followed including the precautions listed below:

  • Read all information in the instruction manual and any other literature included in the box before using the unit.
  • Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your healthcare provider.
  • Operate the unit only as intended. Don’t use it for any other purpose.
  • Warning notices:
    • Regarding the effect of blood flow interference and resulting injury to the patient caused by continuous cuff pressure due to connection tubing kinking
    • Regarding the application of the cuff and its pressurization on any limb where intravascular access or therapy, or an arterio-venous (A-V) shunt is present because of temporary interference to blood flow and could result in injury to the patient.
    • Regarding the application of the cuff and its pressurization on the arm on the side of a mastectomy.

KNOW YOUR UNIT

Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 10

  • Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 112 AAA (LR03) Alkaline BatteriesOrbegozo-TES-3650-Blood-Pressure-Monitor-fig 12
  • Storage Case

BATTERY INSTALLATION/REPLACEMENT

  1. Remove the battery cover from the battery compartment.
  2. Install 2 AAA-size batteries so the + (positive) and – (negative) polarities match the polarities of the battery compartment as indicated.
  3. Replace the battery cover.

Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 13

ATTENTION
  • Do not use rechargeable batteries.
  • Use two identical batteries type AAA. Replace both of the batteries if the symbol of low battery appears on the display.
  • Never leave any low batteries in the compartment since they may leak and cause damage to the unit.

ADJUSTING SETTINGS

  1. To set the year All information will appear when the batteries are installed for the first time. After 2 seconds the year flashes.
    • Press the “MEM” button to increase one year.
    • Press the “SET” button to decrease one year.
    • Long press the button and the value quickly changes.
      Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 14
  2. To set the date and time Press the “MEM” button to change the month and press the “SET” button and continue with the next stepOrbegozo-TES-3650-Blood-Pressure-Monitor-fig 15
    • Then set the day, the hour, and the minute by using the same way. Continue with step 3.
  3. To set unit
    • Then press the “MEM” button again to change the current unit.
    • Press the ” START-STOP” button to save the current setting and turn it off.Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 16
  4. To set the user With the device turned off, the mark of a user will appear when pressing the SET button. Then press SET again to change the current user. Finally, press the START-STOP button to confirm the user and turn it off.Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 17

BEFORE TAKING A MEASUREMENT

Follow these instructions before taking a measurement:

  1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement.
  2. Stress raises blood pressure. Avoid taking measurements during stressful times. Always measure your blood pressure on the same Arm.
  3. Position the unit at heart level throughout the measurement.
  4. Remain still and do not talk during the measurement.
  5. Keep a record of your blood pressure and pulse readings for your physician. A single measurement does not provide an accurate indication of your true blood pressure. You need to take and record several readings over some time. Try to measure your blood pressure at the same time each day for consistency.
  6. Wait 30-60 seconds between measurements. The wait time allows the arteries to return to the condition before taking the blood pressure measurement. You may need to increase the wait time depending on your physiological characteristics.

PROPER WAY OF MEASUREMENT

  • Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 18Remove all clothes from your arm allowing the cuff to fit directly on the skin.Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 19
  • Wrap the cuff tightly around your wrist by using the Velcro strip.Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 20
  • Sit in a chair with your feet flat on the floor.

TAKE A MEASUREMENT

  1. Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 21Press the START-STOP button. All display symbols appear on the screen. The cuff starts to inflate automatically.Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 22
  2. Inflation stops automatically and the measurement is started. The heartbeat symbol flashes once a pulse is detected.Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 23
  3. The blood pressure and pulse rate are displayed when the measurement is completed. The cuff is deflated automatically, and all of the measurement results are stored in the memory with date and time. The “IHB” symbol will be displayed if an irregular heartbeat is detected.Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 24
  4. Press the “START-STOP” button to turn off the unit. The unit will automatically turn off after 2 minutes if you have forgotten to turn it off.
    The unit stores the blood pressure and pulse rate in the memory after completing a measurement every time, up to 2×60 sets. The earliest record is deleted to set the latest measurement taken.

    • NOTE: To stop the inflation or measurement, press the “START STOP” button at any time. The unit will stop inflating and then
      release and turn off.

USE THE MEMORY FUNCTION

Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 25

  1. To read the average value Press the “MEM” button. The average value symbol will be displayed.Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 26
  2. To read the measurement value
    • Press the “MEM” button to view the latest measurement value with the measuring date and time.
    • Press the “SET” button to view the oldest measurement value with the measuring date and time.
  3. To delete the memory valueOrbegozo-TES-3650-Blood-Pressure-Monitor-fig 27
    In the memory reading mode, press the “MEM” button for 4-6 seconds the unit will displayOrbegozo-TES-3650-Blood-Pressure-Monitor-fig 28 Press the “MEM” button again and the LCD will display Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 29

Note:
if you have set, Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 29 but do not press a button for 2 minutes, the product will shut off automatically, but the corresponding user’s blood pressure data will not be deleted. The delete operation must be confirmed by the user.

IRREGULAR HEARTBEAT SYMBOL

Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 30When the unit detects an irregular rhythm two or more times during the measurement, the irregular heartbeat Symbol will appear on the display with the measurement values. If the Irregular Heartbeat Symbol (IHB) displays with your measurement results, we recommend you consult your physician. Follow the directions of your doctor.

ABOUT BLOOD PRESSURE

Blood Circulation

The blood circulation is responsible for supplying the body with oxygen. Blood pressure is the pressure exerted on the arteries. The systolic blood pressure value (higher pressure or top value) represents the blood pressure produced by the contraction of the heart muscle. The diastolic blood pressure value (lower pressure or lower value) represents the blood pressure produced by the relaxation of the heart muscle.Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 31

Health and blood pressure

The incidence of hypertension increases with age. In addition, a lack of exercise, excess body fat, and high levels of cholesterol (LDL), which sticks to the inside of blood vessels, reduces the elasticity of these vessels. Hypertension accelerates arterial sclerosis which can lead to very serious conditions such as stroke and myocardial infarction. For these reasons, it is very important to know whether the blood pressure is within a healthy range. Blood pressure fluctuates from minute to minute, throughout the day. Therefore it is essential to take
regular measurements to help you identify an average blood pressure. Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 32

Classification of blood pressure

After each measurement is completed, the LCD will show your position automatically on the six segments of the bar indicator which corresponds to the World Health Organization (WHO) Blood Pressure Indicator.

*Note! When a person’s systolic and diastolic pressures fall into different categories, the higher category should apply.Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 33

Symptoms of high blood pressure

High blood pressure can go unnoticed for a long time since it does not cause noticeable symptoms. The following are all possible causes of abnormally high blood pressure:

  • Overweight
  • High cholesterol level
  • Smoking
  • Excessive alcohol consumption
  • Stress and emotional upset
  • Excessive consumption of salt
  • Lack of physical exercise
  • Genetic/hereditary predisposition
  • Underlying illnesses, such as kidney disorders or endocrine disturbance
Treatment of high blood pressure

If your blood pressure reaches upper values of 140-160 mmHg and lower values of 90-95 mmHg in repeated measurements over several days, you should consult your doctor for a detailed medical examination. You can assist with the treatment prescribed by your doctor in the following ways:

  • Lose weight and lower your cholesterol level
  • Reduce the consumption of alcohol and salt
  • Stop smoking
  • Take regular exercise
  • Monitor your blood pressure

ERROR INDICATORS

Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 34

ELIMINATE FAULT

Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 35

CLEANING AND MAINTENANCE

  • Do not disassemble the unit
  • Do not fold the cuff or immerse it in water
  • Do not use volatile liquids to clean the main unit
  • Do not use petrol, thinners, or similar solvents to clean the cuff
  • Do not subject the unit to strong shocks or vibrations
  • Do not subject the main unit and the cuff to extreme temperatures, humidity, moisture, or direct sunlight.
  • Do not carry out repairs of any kind yourself. If a defect occurs, please contact your distributor. If needed, please use ultraviolet radiation for disinfection.
  • The unit should be cleaned with a soft, dry cloth.
  • Use a soft, moistened cloth and soap to clean the arm cuff
  • Substitution of a cuff different from that supplied might result in measurement error.

Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 36

SPECIFICATIONS

Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 37 Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 38

INDICATIONS FOR USE STATEMENT

  • Please follow local ordinances or regulations for disposal.
  • Applied part: cuff
  • Protection class: internally powered equipment.
  • Applied part type: type BF.
  • Moisture protection: IPX0, continue operation.
    • Altitude <2000 m.
    • Overvoltage: II
    • Pollution degree: 2
  • The unit might not meet its performance specifications if stored or used outside the following specified temperature and humidity ranges.
  • The unit satisfies the requirements of IEC60601-1 Medical electrical equipment; IEC60601-1-2:2007: Electromagnetic compatibility-Requirements and tests; EN1060-1; Non-invasive sphygmomanometers-Part 1: requirements and test methods for non-automated measurement type; EN1060-3: Non-invasive sphygmomanometers – Part 3: supplementary requirements for electro-mechanical blood pressure measuring systems.

GUIDANCE AND MANUFACTURE’S DECLARATION

Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 39 Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 40

  • NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
  • NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from
    structures, objects, and people.
Recommended separation distances between portable and mobile RF communications equipment and the Digital Blood Pressure Monitor.

The customer or the user of the Digital Blood Pressure Monitor can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the Digital Blood Pressure Monitor as recommended below, according to the maximum output power of the communications equipment.Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 41

  • NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
  • NOTE 2 These guidelines may not apply in all situations.
Disposal of old electrical appliances.

Orbegozo-TES-3650-Blood-Pressure-Monitor-fig 42

The crossed-out “wheeled bin” symbol on the product reminds you of your obligation, that when you dispose of the appliance, it must be separately collected. Consumers should contact their local authority or retailer for information concerning the correct disposal of their old appliances.

DECLARATION OF CONFORMITY:
This device complies with the requirements of the Low Voltage Directive 2006/95/EC and the requirements of the EMC Directive 2004/108/EC.

  • European representative name: ShangHai International Holding Corp. GmbH (Europe) Address: Eiffestrasse 80, 20537 Hamburg Germany
  • Shenzhen Kingyield Technology Co., Ltd. Section C1-2, FuHai Industrial Zone Fuhai Road FuYong Town Bao’an District 518103 Shenzhen City, GuangDong PEOPLE’S REPUBLIC OF CHINA

For More Manuals